Non Default Controller Setting Stage

Kohzu standard stage have various types of home position (origin) return method. Thus, if combination of standard stage and standard stepper motor controller (SC-021/210/410), that method should be changed from default in case.It is trouble you, but check the operation manual about stage sensor type and controller setting when you use.

【The product should be changed system setting and value of controller setting (SYS No.9) 】


Stage type Stage model Number  Setting value(default:3) Home position (origin) return method
X Linear Stage  XA04A-R101(-R)   4  Home position return method is determined with Home position sensor in motion range.
 YA04A-R101 (-RRR) 
 XA04A-R2 (-R) 
 YA04A-R2 (-RRR) 
 XA07A-R2H (-R) 
 YA07A-R2H (-RRR) 
 XA10A-R2H (-R) 
 YA10A-R2H (-RRR) 
 XA16F-L21 (-R)   1  Home position return method is determined with zone (datum) sensor.
 XA16F-L22 (-R) 
 XA16F-L23 (-R) 
Vertical Stage  ZA04A-W1   7 or 8 Home position return method is determined with limit sensor.
 ZA05A-V1(Stop to order Product)   4  home position (origin) return method is determined with Home position sensor in motion range.
 ZA05A-W1 
 ZA05A-W2C 
 ZA07A-V1F 
 ZA10A-32F   1  Home position return method is determined with zone (datum) sensor.
 ZA16A-32F 
Rotation Stage  RA04A-W   7 or 8 Home position return method is determined with limit sensor.
Swivel (Tilt) Stage  SA04B-RT/M (-R)   4  home position return method is determined with Home position sensor in motion range.
 SA05A-R2T/M/B/S/L (-R) 
 SA07A-R2T/M/B/S/L (-R)